Availability: | |
---|---|
Temperature humidity test chamber and thermal shock test chamber have high and low temperature functions, both of which are doing the temperature tests for products.
The difference between temperature humidity test chamber and thermal shock test chamber is that the temperature humidity test chamber is to observe the change of the product in the process of cooling or heating the product, while the thermal shock test chamber does not have this cooling process, it is to make the product instantly sense the change of temperature and change.
Thermal shock test chamber is divided into three-zone type and two-zone type according to test requirements and test standards, the difference is that the test method and internal structure are different.
The three-zone type is divided into cold storage room, heat storage room and test room, and the product is placed in the test room during testing.
Temperature humidity test chamber and thermal shock test chamber have high and low temperature functions, both of which are doing the temperature tests for products.
The difference between temperature humidity test chamber and thermal shock test chamber is that the temperature humidity test chamber is to observe the change of the product in the process of cooling or heating the product, while the thermal shock test chamber does not have this cooling process, it is to make the product instantly sense the change of temperature and change.
Thermal shock test chamber is divided into three-zone type and two-zone type according to test requirements and test standards, the difference is that the test method and internal structure are different.
The three-zone type is divided into cold storage room, heat storage room and test room, and the product is placed in the test room during testing.
Model | 400 Series | 500 Series | |||||||||||
Temperature Performance Parameters | |||||||||||||
Warm-up Range (High Temperature Chamber) | ℃ | 60~200 | |||||||||||
Pre-cooling Range (Low Temperature Chamber) | ℃ | -70~0 | |||||||||||
Impact Temperature Range | ℃ | -40~150 | -55~150 | ||||||||||
Conversion Time | S | 15 | |||||||||||
Revocery Time | min | 5 | |||||||||||
Heating Time (High Temperature Chamber) | min | RT→200℃≤60min | |||||||||||
Cooling Time (Low Temperature Chamber) | min | 25℃→-50℃≤60min | 25℃→-65℃≤60min | ||||||||||
Temperature Fluctuations | ℃ | ≤1 | |||||||||||
Temperature Uniformity | ℃ | ≤2 | |||||||||||
Temperature Deviation | ℃ | ±2 |
Model | 400 Series | 500 Series | |||||||||||
Temperature Performance Parameters | |||||||||||||
Warm-up Range (High Temperature Chamber) | ℃ | 60~200 | |||||||||||
Pre-cooling Range (Low Temperature Chamber) | ℃ | -70~0 | |||||||||||
Impact Temperature Range | ℃ | -40~150 | -55~150 | ||||||||||
Conversion Time | S | 15 | |||||||||||
Revocery Time | min | 5 | |||||||||||
Heating Time (High Temperature Chamber) | min | RT→200℃≤60min | |||||||||||
Cooling Time (Low Temperature Chamber) | min | 25℃→-50℃≤60min | 25℃→-65℃≤60min | ||||||||||
Temperature Fluctuations | ℃ | ≤1 | |||||||||||
Temperature Uniformity | ℃ | ≤2 | |||||||||||
Temperature Deviation | ℃ | ±2 |
STI is a world-famous production reliability test solution provider with 50 years experience in the industry.