Home » Products » Optional Parts » RC-3000 Controller » Digital Vibration Controllers RC-3000

loading

Share to:
pinterest sharing button
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
whatsapp sharing button
sharethis sharing button

Digital Vibration Controllers RC-3000

RC-3000 is aworld-class vibration control system, has full range of functions of vibration tests and dynamic signal analysis. RC-3000 is different from the traditional controller, it uses a LAN directly integrated embedded DSP, which enhances the control performance, system reliability and exceptions protection ability. RC-3000 vibration controller has high reliability and control accuracy and wide dynamic range, the functions of improved automatic safety detection and protection and power-down data protection, and can do the long continuous recording time-domain data and off-line analysis.
 
  • Dynamic Signal Analysis
  • RC-3000 controller with more than 4 channels can choose to add the following dynamic signal analysis functions:
  • Real-time analysis
  • PC offline post-processing
Availability:
ModelSC-3000RC-3000-2/4RC-3000-8RC-3000-16RC-PAD
Random
SOR

ROR

Sine on Random on Random

Sine
Sine Wave Generator
RSTD

Multi Sine

Classical Shock
Transient Shock

Random Shock

SRS

Time Data Replication

Dynamic Signal Analysis


ModelSC-3000RC-3000-2/4RC-3000-8RC-3000-16RC-PAD
Input Channel
Input Channel Number2(can be upgraded to 4 channels)2/4(2 channels can be upgraded to 4 channels)high-channel system through the professional switch)8(More than 8 channels can be connected to162
Max. Sampling Rate102.4kHz102.4kHz102.4kHz102.4kHz102.4kHz
(All channels(All channels(All channels(All channels(All channels
simultaneously)simultaneously)simultaneously)simultaneously)simultaneously)
Input Range± 20V± 20V± 20V± 20V± 20V
Input Coupling methodCharge, voltage or IEPE, single-ended and differential connections, AC or DC couplingCharge, voltage or IEPE, single-ended and differential connections, AC or DC couplingCharge, voltage or IEPE, single-ended and differential connections, AC or DC couplingCharge, voltage or IEPE, single-ended and differential connections, AC or DC couplingCharge, voltage or IEPE, single-ended and differential connections, AC or DC coupling
Dynamic Range>150dB>150dB>150dB>150dB>150dB
A/D24bit24bit24bit24bit24bit
Channel Phase Matching± 0.2degree± 0.2degree± 0.2degree± 0.2degree± 0.2degree
Amplitude Accuracy± 0.2dB± 0.2dB± 0.2dB± 0.2dB± 0.2dB
FilterAnalog anti-aliasing filter, 160dB digital filterAnalog anti-aliasing filter, 160dB digital filterAnalog anti-aliasing filter, 160dB digital filterAnalog anti-aliasing filter, 160dB digital filterAnalog anti-aliasing filter, 160dB digital filter
Output Channel
Output Channel Number1(Drive)2(Drive and COLA)2(Driveand COLA)2(Driveand COLA)1(Drive)
Dynamic Range95dB100dB100dB100dB95dB
Voltage Range± 10V± 10V± 10V± 10V± 10V
D/A24bit24bit24bit24bit24bit
Total Harmonic<-95dB<-95dB<-95dB<-95dB<-95dB
Filter160dB /Oct digital filter, analog filtering160dB /Oct digital filter, analog filtering160dB /Oct digital filter, analog filtering160dB /Oct digital filter, analog filtering160dB /Oct digital filter, analog filtering
RandomGauss signal output, loop-time is 12.5 ms (2 kHz, 200 lines), control dynamic range is 95 dB, frequency range is DC ~ 10 kHz (can be extended to 40 kHz), spectrum lines are 200, 400, 800, 1600, 3200, 6400 (can be extended to 25600), support for the function of non-linear control and kurtosis control, effectively suppress the formant
Sine on Random (SOR)24 frame sine signals, simulate smooth frequency sweep or set frequency sweep, independent stat/stop
Random on Random (ROR)12 random narrow bands, cross frequency sweep, sudden open/close
Random and Sine on Random20 frame plus 12 narrow bands, obtain all features of Sine on Random and Random on Random
Sweep SineFrequency range is 0.5 ~ 10 kHz (can be extended to 0.1 Hz ~ 46 kHz), spectrum Display number of  lines is 256 - 4096, loop time is 10ms, dynamic control range is 100dB, tracking filter,
Resonant Search and Tracked Dwell (RSTD)Resonance recognize based on Q value and amplitude  value, automatic  searching,  set  frequency dwell or tracking dwell
Classical ShockFull impulse spectrum map, impulse width is 1 ms ~ 10000 ms,the average number of control is from 1 to 500, flexible compensation, SRS analysis
Transient ShockFinite-length time waveform control, pre-store waveforms of Bellcore Z1 and Z2, Z3, sine, triangle, white-noise, or transfer into any time domain waveform from the files
Shock Response SpectrumThere are octaves of 1/1, 1/3, 1/6, 1/12, 1/24 and1/48 to be selected. High blast shock, min. acceleration or user-defined duration time, modify, edit or compensate
Time Data ReplicationLong time waveform simulation, provide flexible and easy tools for editing and importing