High Acceleration

The acceleration of normal electro-dynamic vibration test systems without payload is no more than 100g. When actually performing the test, the acceleration will reduce to no more than 50g because of the weight of specimens and fixture. DH high acceleration electro-dynamic shaker can meet test specification requirements of sine 70g, 80g, random 55g refer to different standards.

Features
  • Maximum sine acceleration: 1470m/s²
  • Maximum random acceleration: 980m/s²
  • Optimized structure design
  • Light weight of armature but high strength.
  • Improved winding strength and dielectric strength of armature.
  • High conductivity efficiency and high structural strength.
Availability:


ModelDH-3500-40DH-6000-60DH-8000-80
Max Acceleration (Sine) (m/s²)147014701470
Max Acceleration (Random) (m/s²)980980980
Usable Frequency Range (Hz)2~24002~25002~2500
Rated Sine Force (kN)34.358.878.4
Max Velocity (m/s)222
Max Displacement (mm)515151
Vibrator
Effective Armature Mass (kg)23.34053
Armature Diameter (фmm)320340445